●Product
Guide--Dynamic
Data Acquisitions & Conditioners
Dynamic Data Test & Analysis System
|
²
YE6231 Miniture Dynamic Data
Acquisition (4CH,96kHz) |
|
 |
The 24-bit A/D parallel data
acquisition system based on USB2.0 interface;
Voltage / IEPE input; 4-channel, built-in
programmable gain amplifier; With DC / DC power
supply; low price,lightweight,portabl, easy to
Operating; Suitable for field testing and
teaching . |
|
²
YE6232 Dynamic Data
Acquisition (16/32CH,96k Hz,TEDS) |
|
 |
The 24-bit A / D parallel data
acquisition system based on USB2.0
interface;Voltage / IEPE input; 16/32 channel,
built-in programmable gain amplifier and
real-time digital filters; Supports IEEE P1451.4
for Smart Sensors(TEDS); Suitable for multi-
points testing. |
|
²
YE6233 High Sample Rate Dynamic
Data Acquisition( Up to 3MHz) |
|
 |
The real-time dynamic high-speed
data acquisition system based on USB2.0
interface; Single-channel real-time sampling
rate of 3MHz; 4-channel parallel sampling rate
of 750kHz/CH. Suitable for high sample rate test
as shock and Explosion. |
|
Model |
YE6231 |
YE6232 |
YE6233 |
|
Channels |
4 |
16/32 |
4 |
|
A/D bits |
24bit(∑-△) |
24bit(∑-△) |
16bit |
|
Input
|
V/IEPE |
V/IEPE/TEDS |
V/IEPE |
|
IEPE
Excitation Source |
2mA/+24VDC |
4mA/+24VDC |
4mA/+24VDC |
|
Input
Range |
≤±10VP ; |
≤±10VP |
≤±10VP |
|
Freq. Range |
DC-30kHZ(-3dB±1dB) |
DC-30kHZ(-3dB±1dB) |
DC-500kHZ(-3dB±1dB) |
|
Gain |
X1 X10 X100 |
X1 X10 X100 |
X1 X10 |
|
Filter |
Independent Anti-filtering |
Independent Anti-filtering |
Independent Anti-filtering |
|
Accuacy |
±0.5% |
±0.5% |
±0.5% |
|
Sample rate(Max.) |
96kHz/CH;Parallel |
96kHz/CH,并行Parallel |
750kHz/CH,Parallel
3MHz/CH, Max. |
|
Interface |
USB2.0 |
USB2.0 |
USB2.0 |
|
Trigger |
Signal Trigger
|
Signal Trigger
External trigger |
Signal Trigger
External trigger |
|
Dimensions (mm) |
132W×25.4mmH×160D |
426W´88H´300D(H) |
132W×25.4H×160D |
|
Weight |
0.5Kg |
4 Kg |
0.5Kg |
|
Power Supply |
USB Interface Self-supply |
AC220V 50Hz
DC12V (9 to18V) |
DC12V (9 to18V) |
10.2:
Dynamic Data Acquisitions with
Pre-Amplifiers
|
²
YE6267/YE6277 Multi-channels
Dynamic Data Acquisition (USB2.0) |
|
 |
The 16-bit A/D parallel data
acquisition system based on USB2.0 interface;
The standard voltage / IEPE, Charge,Stain and
more pre-amplifiers input. Automatic identify
and control pre-amplifiers via Virtual panel.
Support for a variety of file storage format,
and file format conversion.YE6277: small
Dimensions, light weight, Easy to expand. |
|
²
YE6268/YE6278
Multi-channels Dynamic Data Acquisition
(IEEE1394) |
|
 |
² The
16-bit A / D parallel data acquisition system
based on IEEE1394 interface;
Support for multiple devices to
expand; Automatic identify and control
pre-amplifiers via Virtual panel. 2 Channels
D/A output(selectable) to provide analog singal
output; YE6278: small Dimensions, light weight,
Easy to expand. |
|
Model |
YE6267 |
YE6277 |
YE6268 |
YE6278 |
|
Channels |
8/16 |
16/32 |
8/16 |
16/32 |
|
A/D bits |
16bits |
24bits(∑-△) |
16bits |
24bits(∑-△) |
|
Interface |
USB2.0 |
USB2.0 |
IEEE1394 |
IEEE1394 |
|
Sample rate(Max.) |
100kHz/Ch |
96kHz/Ch |
200kHz/Ch |
96kHz/Ch |
|
Accuacy |
±0.4% |
±0.4% |
±0.4% |
±0.4% |
|
Anaolg Output |
-- |
-- |
±5VP |
±5VP |
|
D/A |
-- |
-- |
16bits |
16bits |
|
Conversion rate |
-- |
-- |
³50kSPS |
³50kSPS |
|
Filter |
Anti-filtering |
Anti-filtering |
Anti-filtering |
Anti-filtering |
|
Trigger |
Signal/ External Trigger |
Signal/ Externa Trigger |
Signal/ External Trigger |
Signal/ Externa Trigger |
|
Dimensions (mm) |
276W´132.5H´320D |
235W´132.5H´320D |
276W´132.5H´320D |
235W´132.5H´320D |
|
Weight |
5Kg |
3.5 Kg |
5Kg |
3.5 Kg |
|
Power Supply |
AC220V 50Hz |
AC220V 50Hz |
AC220V 50Hz |
AC220V 50Hz |
|
Support
Pre-Amplifiers |
YE3823B |
YE3825A/B |
YE3823B |
YE3825A/B |
|
YE3830B |
YE3812A/B |
YE3830B |
YE3812A/B |
|
YE5864B |
YE5861A/B |
YE5864B |
YE5861A/B |
|
YE5931B |
YE5933A/B |
YE5931B |
YE5933A/B |
|
Control Software |
YE7600 |
YE7600 |
YE7600 |
YE7600 |
YE62 series of dynamic data acquisition system supports a
wide range of pre-conditioning input and automatically
identify the type and
parameter settings, constitute a multi-functional dynamic
testing and analysis system.
10.3:
Pre-Amplifiers for YE62 series
Acquisitions
|
²
YE3823B /YE3825A(B) IEPE/Voltage
Pre-Amplifiers |
|
 |
YE3823B:2CH;
YE3825A:1CH;YE3825B:2CH
Selectable for signal input of
Voltage and IEPE; Supply for IEPE Excitation
source; Test Acceleration,Velocity and
displacement by Double Integrator; |
Input Range |
±5 V |
|
Gain (mV/unit) |
1-1000 adjustable |
|
Frequency Range |
IEPE:0.3-30kHz(-3dB)
Voltage:DC--30kHz(-3dB) |
|
Accuracy |
A:±1%;V:<±3%;D:<±3% |
|
IEPE
Power Supply |
4mA/+24V |
|
Noise |
<5μV(RTI) |
|
²
YE5864B /YE5861A(B) Charge(PE)/IEPE
Pre-Amplifiers |
|
 |
YE5864B:2CH;
YE5861A:1CH; YE5861B:2CH
Selectable for signal input of
Charge and IEPE; Supply for IEPE Excitation
source; Test Acceleration,Velocity and
displacement by Double Integrator;
|
Input Range |
PE:±0.5´105
pC; IEPE: ±5 V |
|
Gain (mV/unit) |
1-1000 adjustable |
|
Frequency Range |
0.3-30kHz(-3dB) |
|
Accuracy |
A:±1%;V:<±3%;D:<±3% |
|
IEPE
Power Supply |
4mA/+24V |
|
Noise(RTI) |
<5μV(RTI) |
|
²
YE3830B /YE3812B Strain
Pre-Amplifiers |
|
 |
YE3830B:2CH;
YE3812A:1CH;YE3812B:2CH
|
Input Range |
0 ±5000με(2VDC) |
|
Sensitivity |
100–4000 adjustable |
|
Accuracy |
<±0.3% |
|
Balance |
±5000με |
|
Noise |
≤3μV(RTI) |
|
Bridge Resistance |
120 - 2000Ω(K=2.00) |
|
DC Bridge Voltage |
1,2,3,10VDC/30mA |
|
Frequency Range |
DC-30kHz(-3dB) |
|
²
YE5931B /YE5933A(B) Eddy
Displacement Pre-Amplifiers |
|
 |
YE5931B:2CH;YE5933A:1CH;YE5933B:2CH |
Input Range |
|
|
Accuracy |
<±0.5%±1μm |
|
Power Supply for Eddy
Transducer |
-24V±5%/15mA |
|
Frequency
Range
|
DC - 10kHz |
|
Zero Range |
±24VDC |
|
Liner |
<±0.2%FS |
YE3823B/YE3830B/YE5864B/YE5931B series of pre-signal
conditioning at the same time can be directly inserted into
the dynamic data acquisition system
YE6267/YE6268 chassis; YE3825A (B) / YE3812A (B) / YE5861A
(B) / YE5933A (B) series of pre - signal conditioning design
of small devices can be directly inserted at the same time
dynamic data acquisition system YE6277/YE6278 chassis; 8-32
convenience channel composed of multi-function dynamic
signal testing, the collection, analysis system; by the
acquisition system of automatic identification channel
types, complete kinds of parameters, automatic completion of
the sampling frequency in accordance with anti-aliasing
filter settings.
|